D1194
BRESTA Solid Timber System
467
mm
R
w
–
Ventilated facade
143
kg/m2
C
–
Calculation without verification
≈
0.155
W/m2 K
C
tr
–
Detail
IFC4 LOD300
XLSX
Test report PDF
D1195
BRESTA Solid Timber System
547
mm
R
w
–
Ventilated facade
157
kg/m2
C
–
Calculation without verification
≈
0.129
W/m2 K
C
tr
–
Detail
IFC4 LOD300
XLSX
Test report PDF
D1196
BRESTA Solid Timber System
627
mm
R
w
–
Ventilated facade
171
kg/m2
C
–
Calculation without verification
≈
0.11
W/m2 K
C
tr
–
Detail
IFC4 LOD300
XLSX
Test report PDF
D1197
Solid timber, derived wood products
325
mm
R
w
65
dB
Compact facade
98
kg/m2
C
-2
dB
Measurement
≈
0.107
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
D1198
Solid timber, derived wood products
335
mm
R
w
65
dB
Compact facade
98
kg/m2
C
-1
dB
Measurement
≈
0.107
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
D1199
Solid timber, derived wood products
250
mm
R
w
40
dB
Compact facade
76
kg/m2
C
-2
dB
Measurement
≈
0.157
W/m2 K
C
tr
-4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
D1200
Solid timber, derived wood products
260
mm
R
w
40
dB
Compact facade
88
kg/m2
C
-2
dB
Measurement
≈
0.157
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
D1201
Solid timber, derived wood products
110
mm
R
w
39
dB
Compact facade
78
kg/m2
C
-2
dB
Measurement
≈
0.474
W/m2 K
C
tr
-3
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
D1231
Stud
235
mm
R
w
45
dB
Compact facade
48
kg/m2
C
-2
dB
Calculation without verification
≈
0.163
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
D1232
Stud
235
mm
R
w
46
dB
Compact facade
48
kg/m2
C
-3
dB
Calculation without verification
≈
0.163
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
D1233
Stud
244
mm
R
w
46
dB
Ventilated facade
72
kg/m2
C
-2
dB
Calculation without verification
≈
0.196
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
D1234
Stud
304
mm
R
w
46
dB
Compact facade
81
kg/m2
C
-2
dB
Calculation without verification
≈
0.163
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
D1235
Stud
364
mm
R
w
46
dB
Compact facade
99
kg/m2
C
-2
dB
Calculation without verification
≈
0.134
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
D1236
Stud
315
mm
R
w
–
Compact facade
63
kg/m2
C
–
Calculation without verification
≈
0.126
W/m2 K
C
tr
–
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
D1237
Stud
304
mm
R
w
46
dB
Ventilated facade
89
kg/m2
C
-2
dB
Calculation without verification
≈
0.155
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
D1247
Stud
243
mm
R
w
44
dB
Compact facade
42
kg/m2
C
-3
dB
Measurement
≈
0.158
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
D1248
Stud
256
mm
R
w
49
dB
Compact facade
56
kg/m2
C
-3
dB
Measurement
≈
0.157
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
D1249
Stud
315
mm
R
w
43
dB
Ventilated facade
67
kg/m2
C
-1
dB
Verified calculation
≈
0.193
W/m2 K
C
tr
-6
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
D1253
Stud
323
mm
R
w
50
dB
Ventilated facade
66
kg/m2
C
-2
dB
Verified calculation
≈
0.162
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
D1257
Stud
323
mm
R
w
51
dB
Ventilated facade
66
kg/m2
C
-2
dB
Verified calculation
≈
0.162
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX